PRODUCT

HV Capacitor Feature Application

  • High Voltage Ceramic Disc Capacitor 20KV 6800PF(20KV 682M)
High Voltage Ceramic Disc Capacitor 20KV 6800PF(20KV 682M)

High Voltage Ceramic Disc Capacitor 20KV 6800PF(20KV 682M)

  • Description:1. High rated voltage 20KV, 6800pf 2. Dielectric strength at 150% rated voltage3. Low dissipation factor at 2%4. Y5V
  • Send Inquiry Now

High Voltage Ceramic Disc Capacitor 20KV 6800PF (20KV 682M)

 

Manufacturer: HVC

 

Series: Ceramic Disc Type Capacitor

 

Capacitance: 6800pf (682M)

 

Voltage - Rated: 20KV

 

Tolerance: M---± 20 %

 

Temperature CoefficientY5V

 

Mounting Type: Leaded,Through Hole

 

Operating Temperature: -25℃~+85℃

 

Dielectric Strength: 150% of rated voltage

 

Dissipation Factor tanδ: 1% 

 

Insulation Resistance: Min. 200 000 MΩ at 25 °C

 

Product Description: 

low esr capacitorceramic capscrew terminal capacitorhigh capacity capacitorcapacitor supplierscrew type terminallead capacitor47uf capacitorcapacitor supplynon polarized capacitorhigh voltage condensercondenser capacitorcondenser bushinghigh capacitorceramic condenserhv ceramic capacitor, ultra high voltage capacitor

 

Application: 

 Insulation Resistance TesterMegohmmetersInsulation Resistance MeterMeggerDigital Insulation TestersInsulation Resistance MeasurementMilliohmetersIR Testers and Micro Ohm MetersLaser Power SupplyLaser Power SystemsLaser Power BeamingLaser Power


Ceramic Capacitor knowledge:

X capacitor is divided into X1, X2, X3, the main differences are: 1. X1 withstand high voltage greater than 2.5 kV, less than or equal to 4 kV, 2. X2 withstand high voltage less than or equal to 2.5 kV, 3. X3 withstand high voltage less than or equal to 1.2 kV.
 
Y capacitor is divided into Y1, Y2, Y3, Y4, the main differences are: 1.Y1 withstand high voltage greater than 8 kV, 2.Y2 withstand high voltage greater than 5 kV, 3.Y3 withstand high voltage n/a 4.Y4 withstand high voltage greater than 2.5 kV.
 
X and Y capacitors are safety gauge capacitors, X capacitors are between the zero wires of the fire wire and Y capacitors are between the fire wire and the ground. They are used in power filter to filter the common mode and differential mode interference respectively. Permissible Peak Pulse Voltage Overvoltage Rank (IEC664) X1 > 2.5kV < 4.0kV III X2 < 2.5kV II X3 < 1.2kV for Safety Grade Application of Safety Grade of Safety Capacitors - Safety Grade of Safety Grade of Safety Grade of Safety Capacitors - Dual Insulation Y1 or Strengthening Insulation < 250V Y2 Basic Insulation or Additional Insulation < 150V < 250V Y3 Basic Insulation Insulation or additional insulation equal to 150V or 250V Y4 basic insulation or additional insulation